Thermometers

  • Filter
  Name SKU Description Category
RIX1100+TST0513+RIX1255A KIT K, J, E, T, B, R, N, S, C THERMOMETER DELUXE SET W CASING COMPLETE WITH SUPER THIN PROBE *Design in Japan. Assembled in Taiwan for Japanese Market.Input TypesK, J, E, T, B, R, N, S, C nine thermocouple types; IP66 water-proof & dust-proof.Data-Logging up to 16000 readings x 2 CH; with Real time recording.Multiple graph/Data table view,Export to MS Excel  .Max/Min/Avg/Hold ; Hi/Lo Alarm Functions.Dual thermocouple inputs; Large LED back-light.Both USB and RS-232 interface cable, with software.IP66, CE and RoHS approved. Thermometers
STY011A-AIRFORCE STY011A 1000c High Temperature Infrared Thermometer (with K temp inpu,PC usb) Rugged & Ergonomic design. High DS ratio. Backlit dual display LCD. New series for general purposes. Ultra low power consumption in shutdown mode. Extended long time measuring reliability. Laser sighting on/off is switchable. C or F selectable. Electronic trigger lock. Temperature data storage. Audible alarms. Infrared thermometers (Portable/Handheld)
GNA3100A-SS-1004V2 800~2400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Two color Non-Contact Fixed Infrared Thermometer SS-100 two color(Si/Si) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 800 ℃ to maximum 2400℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
STY011C-AIRFORCE STY011C-750C Basic Handheld Infrared Thermometer Range:-32-750c Backlit dual display LCD. New series for general purposes. Ultra low power consumption in shutdown mode. Extended long time measuring reliability. Laser sighting on/off is switchable. C or F selectable. Electronic trigger lock. Infrared thermometers (Portable/Handheld)
GNA3101A-2IGA-1004V2 400~1200C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Two color Non-Contact Fixed Infrared Thermometer 2IGA-100 two color(InGaAs/InGaAs) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 400 ℃ to maximum 1200℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
CEN0023B-GERMANY LASER HYBRID IR THERMOMETER WITH BUILT-IN PROBE INPUT,K-TYPE-2 YEARS WARRANTY Product Name: Hybrid Infrared Thermometer Description: This unit is the intelligent non-contact infrared thermometer. Beyond the conventional temperature measuring instruments, two novel functions are build-in. With eSmart function, it is highly beneficial for users to measure the target temperature without knowing and checking the emissivity of material (properties of surface). Moreover, the noticeable color signs alert the user when the temperature over the setting point... Infrared thermometers (Portable/Handheld)
GNA3102A-IR-804V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-80 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. IR-80 is composed of sensor & controller. The measurement temperature displays... Thermometers
GNA3103A-IR-80-H4V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-80-H non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
GNA3104A-IR-404V2 0~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-40 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from -20 ℃ to maximum 1000℃ in the distance of 40:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
GNA3105A-IR-214V2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 0 ℃ to maximum 400℃ in the distance of 12:1 D:S(Distance to Spot). Thermometers
GNA3106A-IR-204v2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA). It can measure from 0 ℃ to maximum 400℃ in the distance of 10:1 D:S (Distance to Spot). Emissivity is 0.95 (fixed). Thermometers
GNA3107A-6-IRMAN -20~600C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the amount of infrared energy emitted from object and transmits standard current output signal (4~20mA) or RS-485 communication output signal. Also, it transmits relay contacts for alarm signal. As 6-IRman is composed of infrared sensor head & LCD display with keypad, you can check the temperature value in real-time at the installation site. You can measure the temperature ranged from -20 to max. 600℃... Thermometers
GNA3108A-10-IRMAN -20~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Measuring range -20~1000℃,Spectral range 8~14㎛,optics 40:1,emissivity 0.10 ~ 0.99 adjustable, output 0~20mA/4~20mA/1~5V& 3m cable. PC software provided Thermometers
GNA3200-COMPACT MULTI ANALOG INPUT INDICATOR Multi-input indicator  has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm Thermometers
GNA3201-L-SHAPE ANGLE ADJUSTABLE BRACKET Bracket is to fix infrared thermometer. Thermometers
GNA3202-Air Purge Jacket Air purge removes dust around infrared thermometer. It can be applicable to IR-20, IR-20-4W, IR-21, IR-40, IR-80, IR-80-H, 6-IRman, SS-100, 2IGA-100 Thermometers
GNA3203-AIR/WATER COOLING JACKET FOR IR-40, IR-80, IR-80-H, 10-IRMAN, 6-IRMAN Water-cooling jacket is to use under the high temperature environment. It makes infrared thermometer cool down and working properly. It can be applicable to IR-40, IR-80, IR-80-H, SS-100, 2IGA-100 Thermometers
GNA3204-AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 Thermometers
GNA3205-2INCH LED DISPLAY GNA3205-2INCH LED DISPLAY Thermometers