TES-1604 AUTORANGING INSULATION TESTER RS-232 Window Version, Data Logger
|
|
Innovational logging feature (7000) to memorize all of measurements from the work place
RS-232 interface with valued software
4,000M W /V Reding/10,000M W analog indication
Backlight illumination
3-3/4 Digital LCD, 4000Count
Auto Range for Mega Ohm range
50 segments Log Scaled Analog Display
Easy to carry testing package
Tests insulation at rated voltage into a 1mA load
200mA short circuit continuity current
Meet VED0413
Auto discharge
|
Insulation Tester
|
|
|
TES-3660 Autoranging Insulation Tester
|
|
Large LCD with analog bar graph and digital display.
250V, 500V, 1000V output voltage for insulation M Ω testing.
4000M Ω insulation testing with automatically switch to voltage measurement.
Lo Ω function for testing connections.
Autodischarge of capacitive voltage charges.
Last reading HOLD display.
AC/DC voltage measurement up to 1000V.
Manual data memory and read function (9 sets).
Meets EN61557 and IEC1010-1, CAT III 1000V.
Size : 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
|
Insulation Tester
|
|
|
TES-1260 Humidity Temperature Meter
|
|
Dual LCD display.
Dew Point Reading.
Wet bulb Reading.
MAX/MIN with Time Stamp.
Data Hold function.
℃ & ℉ Switchable.
DATA memory and read function (99 readings from LCD display)
Auto Power Off.
|
Humidity / Temperature Meter
|
|
|
TES-1360A Humidity/Temperature Meter
|
|
Laboratory
Quality Control
Air-Conditioning
Process Engineering
|
Humidity / Temperature Meter
|
|
|
TES-1361C Datalogging Humidity/ Temperature Meter
|
|
Instant preformance of Humidity measurement by precision thin-film capacity sensor
Dual display LCD / Clock
Compact, light weight & Simple operation
7000 Record Data logging Capacity (Dual Reading)
RS-232 interface (software included)
|
Humidity / Temperature Meter
|
|
|
TES-1362 Printing Humidity Temperature Meter
|
|
Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ).
Dew Point Reading.
Max / Min / Data Hold.
Real Time Stamp.
Periodically Print out from Pre-Set time Interval.
|
Humidity / Temperature Meter
|
|
|
TES-1364/1365 Datalogging Humidity Temperature Meter
|
|
Data Hold & Relative function
Dual LCD display with Bargraph indication
Continues Recorder 15000 data sets(TES-1365)
Dew Point Reading
USB interface & windows software(TES-1365)
Wet bulb Reading
Automatic Timer Recording for Datalogger(TES-1365)
MAX/MIN with Time Stamp
|
Humidity / Temperature Meter
|
|
|
AFLEX-3001/3002 Flexible AC Current Clamp
|
|
True RMS
3000A
Voltage Measurement (AFLEX 3002 only)
Fast Peak Function(30 μs)
MAX/MIN
Auto-Power-Off:30 minutes
Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm |
Flexible AC Current Clamp
|
|
|
AFLEX-3003 Flexible VA Harmonics Tester AFLEX -3005 Flexible Power Quality Tester
|
|
Power Analysis (3005)
W, KW, H.P.
VA ,KVA, VAR, KVAR
PF, Phase Angle( Φ )
Energy (WH, KWH)
Dual displays (W+PF, VA+KVAR)
Balanced 3 Φ Power Quality and Sequence
Harmonics Analysis
True RMS (V and A)
3000 A
Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
Analysis of % THD-F and C.F.
Fast Peak Function (33μs and 39μs)
Programmable PT (1 to 250 )ratios
Auto - Power - Off : 30 Minutes
|
Flexible AC Current Clamp
|
|
|
AFLEX-6300 Graphic Power Quality Analyzer
|
|
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD in W, KW, MW) with Programmable Period
Harmonics Analysis ( V and I ) to the 50th Order
Display of 25 Harmonics in One Screen with Waveform
Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles
Analysis of Total Harmonics Distortion ( % THD-F )
Graphic Phasor Diagram
Programmable PT (1 to 3000) Ratios
Capture 128 Transient Events ( Time + Cycles + Faults )... |
Flexible AC Current Clamp
|
|
|
TES-593 ElectroSmog Meter
|
|
Frequency range 10MHz to 8.0GHz
3 axis isotropic measurements of EMF
Non-directional (isotropic) measurement with three-channel measurement probe
High dynamic range
Configurable alarm threshold and memory function
Easy & safety to use
High frequency (RF) electromagnetic wave field strength measurement
Mobile phone base station antenna radiation power density measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for... |
EMF Tester
|
|
|
TES-92 ElectroSmog Meter
|
|
50 MHz to 3.5 GHz frequency range.
For isotropic measurements of electromagnetic fields.
Non-directional (isotropic ) measurement with three-channel measurement probe.
High dynamic range due to three-channel digital results processing.
Configurable alarm threshold and memory function.
Easy to use
High frequency (RF) electromagnetic wave field strength measurement.
Mobil phone base station antenna radiation power density measurement.
Wireless communication applications (CW , TDMA ,... |
EMF Tester
|
|
|
TES-1390/1391/1392 EMF TesterElectroMagnetic Field Tester
|
|
The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices.
The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths.
Display micro Tesla & milli Gauss in the same tester.
Data hold, Peak hold function
On-line computer (1391/1392) Data logging (1392) function.
|
EMF Tester
|
|
|
TES-1393/1394 ElectroMagnetic Field Tester (W/RS-232)
|
|
The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices.
The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths down to 50Hz/60Hz.
Display micro Tesla & milli Gauss in the same tester.
Data hold, Peak hold function.
USB Optical inter face. (1394)
999 Datalogging... |
EMF Tester
|
|
|
PROVA-5601/5637 Clamp-on Ground Resistance Tester
|
|
Non-Contact Ground Resistance Measurement
No Auxiliary Electrode Needed
Jaw Diameter Φ 23 mm (5601)
Jaw Diameter Φ 35 mm(5637)
0.025 – 1500 Ohm
0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS
116 Sets of Memory(5601,5637)
Programmable Hi and Lo Alarm(5601,5637)
Programmable Data Logging (5601,5637)
Telecommunication
Cable TV system
Electrical Power Plant
Cellular Phone System
Factory and Facility
Gas Station Tank
|
Earth / Ground Tester
|
|
|
TES-1700 Digital Earth Tester
|
|
Capable of measuring earth voltage.
Data hold , MAX / MIN function.
Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard... |
Earth / Ground Tester
|
|
|
TES-1605 Digital Earth Tester
|
|
Capable of measuring earth voltage.
Data hold function.
Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
Automatic... |
Earth / Ground Tester
|
|
|
CM-01 DC/AC Clamp Meter
|
|
High Resolution DC/AC 10mA
23 mm Large Jaw Diameter
One Touch Zero for DCA adjustment
|
DC/AC Current Clamp Meter
|
|
|
CM-02/04 Clamp Meter/Automotive Clamp
|
|
DC/AC 0.01A Resolution
AC/DC 0.01A~200A
23mm Jaw Diameter
One Touch Zero
Temperature and Capacitance
Auto Range V、 W 、Hz、℃、
3 3/4 Digits (4000 Counts)
0~9999 RPM(CM-04)
|
DC/AC Current Clamp Meter
|
|
|
CM-03 Leakage Current Tester
|
|
10 m A Ultra High Resolution
Large Conductor Diameter (30mm)
ACA 5 Ranges (40mA, 400mA, 4A, 40A, 100A)
|
DC/AC Current Clamp Meter
|
|