DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire)
|
|
Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire)
Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure
Easier calibration done with standard solution
Auto determination of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-1 - 14
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HDM-137A(2-wire)/HDM-138A(4-wire)
|
|
Industrial ORP Transmitter HDM-137A(2-wire)/HDM-138A(4-wire)
Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum enclosure
Automatic check done with standard solution
Auto-detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-160/HBM-162(4-wire)
|
|
Industrial pH/ORP Transmitter HBM-160/HBM-162(4-wire)
Multi-function pH/ORP analyzer for field installation in a compact aluminum diecast enclosure
One-touch calibration and various self-diagnostic functions
2-point contact signal and 2-channel output including temperature (RS-232 optional)
Power supply: AC90~264V, 50/60Hz
Meas. range
pH meter (HBM-160) : pH -1 - 15 ORP meter (HBM-162) : ORP -2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
|
|
Immersion Type Holder for Replaceable Tip Electrode HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
HC-G70: Transparent PVC holder (heat resistance: 60 degrees C) and semi-transparent PP holder (heat resistance: 80 degrees C) available
HC-G72: SUS316 holder (heat resistance: 80 degrees C)
Length: 0.5 - 3.0m
KCl refillable type stores KCl inside the holder
Mounting bracket/flange available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G95 (KCl Replenish-Free)
|
|
Drop-In Type Detector for Replaceable Tip Electrode HC-G95 (KCl Replenish-Free)
Two selections: throw-in type for deep tanks or drop-in type with a protection pipe
Made from transparent PVC (heat resistance: 60 degrees C)
SUS protection pipe (maximum length: 5 m) and mounting bracket available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
|
|
Flow-Through Type Holder for Replaceable Tip Electrodes HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
HC-G80: Transparent holders made of PVC (heat resistance: 60 degrees C) ; maximum pressure resistance: 0.15MPa
HC-G82: PP/SUS316 part (heat resistance: 80 degrees C) and PVDF/SUS316 part (heat resistance: 100 degrees C) ; maximum pressure resistance: 0.3 MPa
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA PHC-7D
|
|
Immersion Type Sensor with Pulse Air Jet Cleaner PHC-7D
Immersion type pH/ORP electrode holder combined with pulse air jet cleaner
Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water
High cleaning effect due to air bubbles present in the water stream randomly hitting the electrode
No consumables required, such as reagents, brushes
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-100A / HBM-102A
|
|
Compact DIN 96 size design
Auto-detection of electrode deterioration
Automated self-diagnosis of fault (burn-out output)
Alterable alarm contact signal (4-point)
2-channel output (RS-232 optional)
Meas. range:
HBM-100A: pH; -1 - 15 HBM-102A: ORP; -2000 - +2000 mV |
Panel Mount pH/ORP Analyaer
|
|
|
DKK-TOA GSS‐304B(KCl Replenish-Free) / GSS‐314B(KCl Refillable)
|
|
Easy-to-replace electrode tip and reference electrode junction tip
Alkali-resistant glass tips and hydrofluoric-acid-resistant glass tips available
KCl non-refillable type for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
pH: 0 - 14
|
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
|
|
Exchangeable Tip ORP Electrode PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
asy-to-replace electrode tip and reference electrode junction tip
Platinum electrodes (PSS) and gold electrodes (ASS) available
KCl non-refillable type is ideal for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
ORP: -2000 - +2000 mV |
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA HC-7 Series
|
|
Ideal for pH/ORP measurements in tanks and open water applications
Assemble electrodes available: 5600 (KCl refillable type); 5910 (KCl replenish-free type)
Mounting flanges for tanks available (50A, 100A, 150A)
|
Immersion Type pH/ORP Detector
|
|
|
DKK-TOA HC-8Series
|
|
Designed for pH/ORP measurements in closed loop lines and environments where process pressure exists, such as pipes or sealed tanks and etc.
Assemble electrodes available: 5610(KCl refillable type); 5910(KCl replenish-free type)
|
Flow-Through Type pH/ORP Detector
|
|
|
DKK-TOA HC-64
|
|
Ideal for pure water measurements like boiler water (low electric conductivity)
Low flow injection of sampling allows for accurate measurement
Assemble electrodes available: MG-511-2F (glass electrode) 4164-2F (reference electrode) 6149-2F (temperature compensation electrode)
|
pH Sensor for Pure Water Measurement
|
|
|
DKK-TOA LHC-7D
|
|
Electrode Holder with Lift Up Type Jet Cleaner LHC-7D
A detector which can lift up from the sample water and remove fouling from the pH/ORP electrode effectively.
Automatic cleaning system that applies alternate streams of wash water and chemical solution (such as a 5% hydrochloric acid solution) to clean the pH/ORP detector.
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA UHC-7C / UHC-8C
|
|
Flow-Through Type Detector with Ultrasonic Cleaner UHC-7C / UHC-8C
Detectors composed of holder and ultrasonic cleaner: Immersion type (UHC-7C) and flow-through type (UHC-8C)
One-touch detachable holder enables quick calibration and easy maintenance
Compatible with GSS series
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA JHC-7C/JHC-8C
|
|
Immersion Type Detector with Water Jet Cleaner JHC-7C/JHC-8C
Detectors composed of holder and water-jet cleaner: Immersion type(JHC-7C) and flow-through type(JHC-8C)
By spraying water onto the tip of electrode, the water pressure washes fouling away
One-touch detachable holder and easy maintenance
Simple installation with a sensor, timer&electromagnetic valve integrated unit
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA BHC-7C
|
|
Immersion Type pH/ORP Detector with Brush Cleaner BHC-7C
Immersion type pH/ORP electrode holder with cleaning brush (BHC-7C)
The swing movements wash the electrode tip and prevent it from fouling
One-touch detachable holder and easy maintenance
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA RHC-7C / RHC-7EC
|
|
Immersion Type Detector with Chemical Cleaner RHC-7C / RHC-7EC
Immersion type electrode holder combined with chemical cleaning system
By spraying mixed air&cleaning agents onto the electrode tip it dissolves fouling away
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA MAC-355
|
|
pH Meter with Auto Calibration MAC-355
Automatic cleaning and 2-point calibration functions serve long-term reliable pH measurement with just little maintenance
Lift-up type design incorporated with air jet cleaning allows for superior cleaning effect and stable measurement
Self-diagnosis and useful message display
Meas. range
pH: -1 - 15
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|